Dataset Restricted Access
<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
<identifier identifierType="DOI">10.14278/rodare.2537</identifier>
<creators>
<creator>
<creatorName>Kulenkampff, Johannes</creatorName>
<givenName>Johannes</givenName>
<familyName>Kulenkampff</familyName>
<nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0001-6566-5829</nameIdentifier>
<affiliation>HZDR</affiliation>
</creator>
</creators>
<titles>
<title>µCT data of two drill cores of fractured crystalline rock (Grimsel)</title>
</titles>
<publisher>Rodare</publisher>
<publicationYear>2023</publicationYear>
<subjects>
<subject>X-ray computed tomography</subject>
<subject>crystalline rock</subject>
<subject>granite</subject>
<subject>drill core</subject>
<subject>fracture</subject>
</subjects>
<dates>
<date dateType="Issued">2023-11-01</date>
</dates>
<language>en</language>
<resourceType resourceTypeGeneral="Dataset"/>
<alternateIdentifiers>
<alternateIdentifier alternateIdentifierType="url">https://rodare.hzdr.de/record/2537</alternateIdentifier>
</alternateIdentifiers>
<relatedIdentifiers>
<relatedIdentifier relatedIdentifierType="URL" relationType="IsIdenticalTo">https://www.hzdr.de/publications/Publ-37750</relatedIdentifier>
<relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.14278/rodare.2536</relatedIdentifier>
<relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://rodare.hzdr.de/communities/ecfunded</relatedIdentifier>
<relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://rodare.hzdr.de/communities/fwo</relatedIdentifier>
<relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://rodare.hzdr.de/communities/rodare</relatedIdentifier>
</relatedIdentifiers>
<version>1.0</version>
<rightsList>
<rights rightsURI="info:eu-repo/semantics/restrictedAccess">Restricted Access</rights>
</rightsList>
<descriptions>
<description descriptionType="Abstract"><p>Two crystalline rock drill cores from the Grimsel site were scanned with a Nikon XT H 225 - scanner. The samples were prepared (formatted and cast in epoxy) by UJV Rez, Czech Republic. The CT-data were acquired and processed at HZDR-FWOT.</p>
<p>Sample 1 (GAM_UJV_1C_1) contains a complex system of interconnected fractures.<br>
Sample 2 (GAM_UJV_1C_2) contains one single end-to-end fracture with larger aperture.</p>
<p>Size of both samples: Diameter 80 mm, length 165 mm.</p>
<p>Two tomograms were acquired for both samples:<br>
1) Complete drill core as one scan, voxel size ca. 75 &micro;m.<br>
2) HR-tomogram merged from three sections with maximum resolution, voxel size ca. 40 &micro;m.</p>
<p>The tomograms were stored as 3D-raw files. Data format, acquisition parameters, and processing workflow, are documented in the tomogram header files (nrrd-format (text):&nbsp; see https://teem.sourceforge.net/nrrd/format.html).<br>
This data format is importable into open-source visualization programs as 3D slicer (https://www.slicer.org) or Paraview (https://www.paraview.org). The data processing has been conducted with Avizo (https://www.thermofisher.com/de/de/home/electron-microscopy/products/software-em-3d-vis/avizo-software.html).</p>
<p>Files:<br>
Sample 1<br>
GAM_UJV_1C_1_complet-2_01_NLM: Graylevel image of complete sample, ring artifact removal, non-local-means filter<br>
GAM_UJV_1C_1_complet-2_01_thresholded: Tentative label image of complete sample, threshold segmentation with manual edit<br>
Merged-GAM_UJV_1C_1_HR.Frac_section: Graylevel image of merged fracture section, unfiltered<br>
Merged-GAM_UJV_1C_1_HR.Frac_section.Threshold: Tentative label image of merged fracture section, adaptive threshold segmentation with manual edit<br>
GAM_UJV_1C_1_complet_2.png: Figure of complete sample&nbsp;<br>
GAM_UJV_1C_1_HR_Frac_Y2.png: Figure of merged high-resolution tomogram</p>
<p>Sample 2<br>
GAM_UJV_1C_2_complet_01.filtered: Graylevel image of complete sample, ring artifact removal, non-local-means filter<br>
GAM_UJV_1C_2_complet_01.filtered.thresholded: Tentative label image of complete sample, &nbsp;threshold segmentation with manual edit<br>
Merged-GAM_UJV_1C_2_A_01.Frac_section.filtered: Graylevel image of merged fracture section, ring artifact removal, non-local-means filter<br>
Merged-GAM_UJV_1C_2_A_01.Frac_section.filtered.segm: Tentative label image of merged fracture section, threshold segmentation with manual edit<br>
GAM_UJV_1C_2_complett_2.png: Figure of complete sample<br>
GAM_UJV_1C_2_HR_Frac_Y2.png: Figure of merged high-resolution tomogram</p>
<p>Original acquistion data are stored on the HZDR bulk data storage system and available for reprocessing on request.</p>
<p><br>
Financial support was granted from the European Union&rsquo;s Horizon 2020 research and innovation program under grant agreement No. 847593 (EURAD, WP FUTURE, task 2.2).<br>
&nbsp;</p></description>
</descriptions>
<fundingReferences>
<fundingReference>
<funderName>European Commission</funderName>
<funderIdentifier funderIdentifierType="Crossref Funder ID">10.13039/501100000780</funderIdentifier>
<awardNumber awardURI="info:eu-repo/grantAgreement/EC/H2020/847593/">847593</awardNumber>
<awardTitle>European Joint Programme on Radioactive Waste Management</awardTitle>
</fundingReference>
</fundingReferences>
</resource>
| All versions | This version | |
|---|---|---|
| Views | 511 | 511 |
| Downloads | 85 | 85 |
| Data volume | 315.8 GB | 315.8 GB |
| Unique views | 433 | 433 |
| Unique downloads | 16 | 16 |