Dataset Restricted Access

Cyclotron production and purification of 83Sr as a 90Sr substitute for Positron Emission Tomography (PET) - data publication

Lindemann, Marcel; Schöngart, Jann; Štursa, Jan; Franke, Karsten


JSON-LD (schema.org) Export

{
  "@type": "Dataset", 
  "sameAs": [
    "https://www.hzdr.de/publications/Publ-42922"
  ], 
  "description": "<p>Data of a PTFE phantom filled with 83Sr tracer as supplemental information of the publication &quot;Cyclotron production and purification of 83Sr as a 90Sr substitute for Positron Emission Tomography (PET) &quot;</p>\n\n<p><br>\nThe data in this publication consists of:</p>\n\n<p>&micro;CT data</p>\n\n<p>Phantom_nlm_uint16_1081x1068x919_50um.raw:&nbsp; &micro;CT of the Phantom. Voxel size = 50 &micro;m. Format: 3D-array of uInt16, x=1:1081, y=1:1068, z=1:919.</p>\n\n<p><br>\nPositron emission tomography data</p>\n\n<p>Phantom_PTFE_83Sr_PET:&nbsp; PET data is stored as three-dimensional binary arrays of floats, with a voxel size of 1.15 mm. *.v contains the volume, *.hv contains the interfile header</p>\n\n<p>The data is presented with the Scatter, Random and RandomMismatch-Corrections from STIR (Thielemans et al., 2012) applied.</p>\n\n<p><br>\nPlease note: There is a fiducial present in both CT (2x10mm cylinder attached to the outer wall), as well as in PET data.<br>\nThe positions of those does NOT coincide in the presented data, as the CT data was acquired for a different experiment, and alignment for this study was instead conducted based on the bore hole positions.</p>", 
  "@id": "https://doi.org/10.14278/rodare.4483", 
  "identifier": "https://doi.org/10.14278/rodare.4483", 
  "@context": "https://schema.org/", 
  "creator": [
    {
      "@id": "https://orcid.org/0000-0002-5883-8004", 
      "@type": "Person", 
      "name": "Lindemann, Marcel", 
      "affiliation": "HZDR"
    }, 
    {
      "@id": "https://orcid.org/0000-0002-9224-6934", 
      "@type": "Person", 
      "name": "Sch\u00f6ngart, Jann", 
      "affiliation": "HZDR"
    }, 
    {
      "@id": "https://orcid.org/0000-0002-2998-7000", 
      "@type": "Person", 
      "name": "\u0160tursa, Jan", 
      "affiliation": "Nuclear Physics Institute CAS,"
    }, 
    {
      "@id": "https://orcid.org/0000-0003-1831-5353", 
      "@type": "Person", 
      "name": "Franke, Karsten", 
      "affiliation": "HZDR"
    }
  ], 
  "url": "https://rodare.hzdr.de/record/4483", 
  "datePublished": "2026-01-29", 
  "keywords": [
    "positron emission tomography", 
    "computed tomography"
  ], 
  "name": "Cyclotron production and purification of 83Sr as a 90Sr substitute for Positron Emission Tomography (PET) - data publication"
}
27
0
views
downloads
All versions This version
Views 2727
Downloads 00
Data volume 0 Bytes0 Bytes
Unique views 2727
Unique downloads 00

Share

Cite as