First tests of the NOVO Compact Detector Array at a Proton Facility (OncoRay)

Müller, Sara Tabea; Akgun, Bora; Bekkevoll, Anna; Blorstad Thu, Sander; Engebertsen, Anders; Jagt, Thyrza; Pausch, Guntram; Phan, Than Binh; Ratliff, Hunter; Römer, Katja; Smeland Ytre-Hauge, Kristian; Stokkevag, Camilla; Tarakoglu, Engin; Turko, Joseph; Wolf, Andreas; Yazici, Berkay; Meric, Ilker; Kögler, Toni

This data set contains the experimental raw data of the NOVO compact detector array (NOVCoDA) from the measurement campaign at OncoRay Dresden, Germany in December 2025. This experiment is the first test of the NOVCoDA prototype at a clinical proton beam. The aim of the measurement campaign was to characterize the response behavior of the scintillators used under high-energy neutron irradiation (especially the pulse-shape discrimination behavior), as well as to test the imaging, range-shift, and rate-processing capabilities of the system.

Setup:

Measurements 01.12.-09.12.:  miniNOVO (version 5): The prototype consists of 12 organic scintillator elements (6 × M600 and 6 × organic glas scintillator) of the dimensions 12×12×140 mm3

Measurements 10.12.-12.12.:  miniNOVO (version 5.1): The prototype consists of 14 organic scintillator elements (7 × M600 and 7 × organic glas scintillator) of the dimensions 12×12×140 mm3

The scintillator bars have dual readout composed of

The data was recorded with 2 CAEN V1730S3 14-bit, 16-channel digitizers (named dta and dtb) with a sampling frequency of 425.216 MS/s.

The detector array was placed at 90° w.r.t. to the fixed-beam research beam line of the Dresden proton therapy facility at OncoRay, Dresden. A cylindrical PMMA (solid/with air gap/with bone insert) was placed centrally in front of the detector head and irradiated with proton energies from 75-225 MeV and varying currents between 10-2000 pA at various positions (± 180 mm w.r.t. central position).

In addition measurements with the online-adaptive RAPTOR phantom in different configurations (air insert/bone insert/swelling/no swelling) were executed.

Data structure:

The directory DOI_calibration contains the position calibration measurements with a Sr-90 source. Energy_calibration holds the energy calibration measurements with a Na-22 and Cs-137 source. In efficiency_measurement the measurements with a Na-22 source at phantom position (with and without PMMA phantom) can be found. PMMA_phantom is dedicated to all the beam measurements with the cylindrical phantom (with and without various inserts) while the directory online_adaptive_phantom provides the same for the measurements with the RAPTOR phantom. All measurements for which waveforms were recorded are stored in waveforms and backend_comparison is comprised of repeat measurements with the cylindrical PMMA phantom where one detector (dtb, ch2 and ch3) was connected to an alternative back-end system for comparison. All other measurements and test runs are in the tests folder.

The PDF-files 2025-12_ NOVO-first-proton-facility-tests-PGTV-Wiki.pdf and 2025-12_ NOVO-first-proton-facility-tests-Week-2-PGTV-Wiki.pdf hold information about the setup of the experiment and and more details about the individual measurements (elog). The file 2025-12_ NOVO-first-proton-facility-tests-Run-List-PGTV-Wiki.pdf contains the run list with all parameters for each measurement.

In 2025-12_OncoRay_HEBC_Monitor_Data.zip csv-files with the beam control meta data can be found (one file for each measurement day).

The main configuration file for the digitizers is called template_main.cfg.

Data Format:

All data is saved in root files which each contain two root trees, one for each digitizer, named “dta” and “dtb”. The trees hold the following information in the form of listmode data for each event: digitizer channel ("channel"), charge integrated over long gate ("Elong"), charge integrated over short gate ("Eshort"), digitizer flags ("flags") and the timestamp (separated in three parts: "timestamp", "timestampExtended", "time"). Additionally, the root files also contain an TArrayD which denotes the start time of the measurement in UNIX time at its first index and the stop time at its second.

There are two configuration files for each data file (named “filename_dtx.config”), one for each digitizer card. These text files contain the information about the digitizer settings for each run.

[1] Hamamatsu Photonics Deutschland GmbH, Arzbergerstr. 10, 82211 Herrsching am Ammersee, Germany.

[2] Target Systemelektronik, Heinz-Fangman-Straße 4, 42287 Wuppertal, Germany. 

[3] CAEN S.p.A., Via Vetraia 11, 55049 Viareggio (LU), Italy.

The NOVO project has received funding from the European Innovation Council (EIC) under grant agreement No. 101130979. The EIC receives support from the European Union's Horizon Europe research and innovation programme. Partners from The University of Manchester have received funding from UK Research and Innovation under grant agreement No. 10102118
Restricted Access

You may request access to the files in this upload, provided that you fulfil the conditions below. The decision whether to grant/deny access is solely under the responsibility of the record owner.


Access to the data will be granted to eligible persons upon reasonable request, e.g., for validation purposes or as a training dataset for machine learning. Before providing of the data, a mutual agreement on a potential co-authorship (or acknowledgment) for any publications resulting from this data should be made based on good scientific practice. The eligible persons must also comply that this data has to remain restricted. We encourage that eligible persons add their own results of the benchmark test to this repository as a new version.


99
8
views
downloads
All versions This version
Views 9999
Downloads 88
Data volume 20.9 MB20.9 MB
Unique views 8888
Unique downloads 66

Share

Cite as