Dataset Closed Access

Dataset for the publication "Depth distribution of irradiation-induced dislocation loops in an Fe-9Cr model alloy irradiated with Fe ions: The effect of ion energy"

Vogel, Karin; Chekhonin, Paul; Bergner, Frank


JSON Export

{
  "created": "2020-12-15T11:27:46.219340+00:00", 
  "owners": [
    22
  ], 
  "links": {
    "badge": "https://rodare.hzdr.de/badge/doi/10.14278/rodare.671.svg", 
    "doi": "https://doi.org/10.14278/rodare.671", 
    "conceptbadge": "https://rodare.hzdr.de/badge/doi/10.14278/rodare.670.svg", 
    "conceptdoi": "https://doi.org/10.14278/rodare.670", 
    "thumb250": "https://rodare.hzdr.de/api/iiif/v2/e5d72c07-e82a-4bc8-a5a9-ab952907e7e0:4da36007-c475-4b9a-9efe-54a922c4bbdd:Fig1_EBSD.tif/full/250,/0/default.jpg", 
    "html": "https://rodare.hzdr.de/record/671", 
    "latest": "https://rodare.hzdr.de/api/records/671", 
    "latest_html": "https://rodare.hzdr.de/record/671"
  }, 
  "stats": {
    "volume": 0.0, 
    "unique_downloads": 0.0, 
    "version_unique_downloads": 0.0, 
    "unique_views": 186.0, 
    "downloads": 0.0, 
    "version_unique_views": 186.0, 
    "version_views": 557.0, 
    "version_downloads": 0.0, 
    "version_volume": 0.0, 
    "views": 557.0
  }, 
  "doi": "10.14278/rodare.671", 
  "conceptrecid": "670", 
  "conceptdoi": "10.14278/rodare.670", 
  "updated": "2021-11-29T14:32:53.059135+00:00", 
  "revision": 5, 
  "metadata": {
    "relations": {
      "version": [
        {
          "parent": {
            "pid_type": "recid", 
            "pid_value": "670"
          }, 
          "index": 0, 
          "count": 1, 
          "last_child": {
            "pid_type": "recid", 
            "pid_value": "671"
          }, 
          "is_last": true
        }
      ]
    }, 
    "resource_type": {
      "title": "Dataset", 
      "type": "dataset"
    }, 
    "grants": [
      {
        "title": "MULTISCALE MODELLING FOR FUSION AND FISSION MATERIALS", 
        "program": "H2020", 
        "acronym": "M4F", 
        "funder": {
          "links": {
            "self": "https://rodare.hzdr.de/api/funders/10.13039/501100000780"
          }, 
          "acronyms": [
            "EC"
          ], 
          "name": "European Commission", 
          "doi": "10.13039/501100000780"
        }, 
        "links": {
          "self": "https://rodare.hzdr.de/api/grants/10.13039/501100000780::755039"
        }, 
        "code": "755039"
      }
    ], 
    "creators": [
      {
        "name": "Vogel, Karin", 
        "affiliation": "HZDR"
      }, 
      {
        "name": "Chekhonin, Paul", 
        "affiliation": "HZDR"
      }, 
      {
        "orcid": "0000-0002-4058-1044", 
        "name": "Bergner, Frank", 
        "affiliation": "HZDR"
      }
    ], 
    "version": "1", 
    "pub_id": "31890", 
    "communities": [
      {
        "id": "ecfunded"
      }, 
      {
        "id": "rodare"
      }
    ], 
    "keywords": [
      "Fe-9Cr", 
      "Ion irradiation", 
      "Cross-sectional scanning transmission electron microscopy (STEM)"
    ], 
    "title": "Dataset for the publication \"Depth distribution of irradiation-induced dislocation loops in an Fe-9Cr model alloy irradiated with Fe ions: The effect of ion energy\"", 
    "language": "eng", 
    "description": "<p>The dataset covers the raw/processed data required to reproduce the findings derived in the publication &quot;Depth distribution of irradiation-induced dislocation loops in an Fe-9Cr model alloy irradiated with Fe ions: The effect of ion energy&quot; by K. Vogel, P. Chekhonin, C. Kaden, M. Hern&aacute;ndez-Mayoral, S. Akhmadaliev and F. Bergner. The whole set of original figures included in the publication is included as TIFF files. Supplementary material is provided as follows:</p>\n\n<ul>\n\t<li>G385_xMeV_loop_count.pptx: Powerpoint files related to the estimation of the loop concentrations for the 1 MeV and 5 MeV irradiations,</li>\n\t<li>Image_FIB_Position_Final.pptx: Powerpoint file showing the way how the 5 MeV FIB lamella was taken,</li>\n\t<li>Loop_size_xMeV_Slicey.xlsx: Excel files related to the sizing of loops utilized to derive the histograms of the loops sizes,</li>\n\t<li>Thickness_Profile_CBED_5MeV.xlsx: Thickness measurement for 5 MeV using the method of CBED.</li>\n</ul>", 
    "publication_date": "2020-12-15", 
    "access_right": "closed", 
    "doc_id": "1", 
    "doi": "10.14278/rodare.671", 
    "access_right_category": "danger", 
    "related_identifiers": [
      {
        "scheme": "url", 
        "relation": "isIdenticalTo", 
        "identifier": "https://www.hzdr.de/publications/Publ-31890"
      }, 
      {
        "scheme": "url", 
        "relation": "isReferencedBy", 
        "identifier": "https://www.hzdr.de/publications/Publ-31891"
      }, 
      {
        "scheme": "doi", 
        "relation": "isVersionOf", 
        "identifier": "10.14278/rodare.670"
      }
    ]
  }, 
  "id": 671
}
557
0
views
downloads
All versions This version
Views 557557
Downloads 00
Data volume 0 Bytes0 Bytes
Unique views 186186
Unique downloads 00

Share

Cite as