Dataset Restricted Access
Marchini, Sara; Vishwakarma, Vineet; Schubert, Markus; Hampel, Uwe
<?xml version='1.0' encoding='utf-8'?> <resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd"> <identifier identifierType="DOI">10.14278/rodare.603</identifier> <creators> <creator> <creatorName>Marchini, Sara</creatorName> <givenName>Sara</givenName> <familyName>Marchini</familyName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-7620-1349</nameIdentifier> <affiliation>TU Dresden ; HZDR</affiliation> </creator> <creator> <creatorName>Vishwakarma, Vineet</creatorName> <givenName>Vineet</givenName> <familyName>Vishwakarma</familyName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-5428-4112</nameIdentifier> <affiliation>HZDR</affiliation> </creator> <creator> <creatorName>Schubert, Markus</creatorName> <givenName>Markus</givenName> <familyName>Schubert</familyName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-6218-0989</nameIdentifier> <affiliation>HZDR</affiliation> </creator> <creator> <creatorName>Hampel, Uwe</creatorName> <givenName>Uwe</givenName> <familyName>Hampel</familyName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-7371-0148</nameIdentifier> <affiliation>HZDR; TU Dresden</affiliation> </creator> </creators> <titles> <title>Experimental liquid concentration distribution for air-led stripping of isobutyl acetate in sieve tray column</title> </titles> <publisher>Rodare</publisher> <publicationYear>2020</publicationYear> <subjects> <subject>distillation</subject> <subject>concentration distribution</subject> <subject>sieve tray</subject> <subject>point efficiency</subject> <subject>tray efficiency</subject> </subjects> <dates> <date dateType="Issued">2020-11-26</date> </dates> <language>en</language> <resourceType resourceTypeGeneral="Dataset"/> <alternateIdentifiers> <alternateIdentifier alternateIdentifierType="url">https://rodare.hzdr.de/record/603</alternateIdentifier> </alternateIdentifiers> <relatedIdentifiers> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsReferencedBy">10.1021/acs.iecr.0c05962</relatedIdentifier> <relatedIdentifier relatedIdentifierType="URL" relationType="IsIdenticalTo">https://www.hzdr.de/publications/Publ-31789</relatedIdentifier> <relatedIdentifier relatedIdentifierType="URL" relationType="IsReferencedBy">https://www.hzdr.de/publications/Publ-31747</relatedIdentifier> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.14278/rodare.602</relatedIdentifier> <relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://rodare.hzdr.de/communities/rodare</relatedIdentifier> <relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://rodare.hzdr.de/communities/topflow</relatedIdentifier> </relatedIdentifiers> <rightsList> <rights rightsURI="info:eu-repo/semantics/restrictedAccess">Restricted Access</rights> </rightsList> <descriptions> <description descriptionType="Abstract"><p>This data contain the outcome of absorbance measurements performed via UV-Spectroscopy on liquid samples containing isobutyl acetate in various concentration. The liquid samples have been taken from several deck positions on a distillation sieve tray to determine the liquid concentration distribution and have been used to determine tray and point efficiency in a post-processing stage.</p></description> </descriptions> </resource>
All versions | This version | |
---|---|---|
Views | 591 | 591 |
Downloads | 1 | 1 |
Data volume | 1.4 kB | 1.4 kB |
Unique views | 291 | 291 |
Unique downloads | 1 | 1 |