Dataset Restricted Access
Marchini, Sara;
Vishwakarma, Vineet;
Schubert, Markus;
Hampel, Uwe
<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
<identifier identifierType="DOI">10.14278/rodare.603</identifier>
<creators>
<creator>
<creatorName>Marchini, Sara</creatorName>
<givenName>Sara</givenName>
<familyName>Marchini</familyName>
<nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-7620-1349</nameIdentifier>
<affiliation>TU Dresden ; HZDR</affiliation>
</creator>
<creator>
<creatorName>Vishwakarma, Vineet</creatorName>
<givenName>Vineet</givenName>
<familyName>Vishwakarma</familyName>
<nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-5428-4112</nameIdentifier>
<affiliation>HZDR</affiliation>
</creator>
<creator>
<creatorName>Schubert, Markus</creatorName>
<givenName>Markus</givenName>
<familyName>Schubert</familyName>
<nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-6218-0989</nameIdentifier>
<affiliation>HZDR</affiliation>
</creator>
<creator>
<creatorName>Hampel, Uwe</creatorName>
<givenName>Uwe</givenName>
<familyName>Hampel</familyName>
<nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-7371-0148</nameIdentifier>
<affiliation>HZDR; TU Dresden</affiliation>
</creator>
</creators>
<titles>
<title>Experimental liquid concentration distribution for air-led stripping of isobutyl acetate in sieve tray column</title>
</titles>
<publisher>Rodare</publisher>
<publicationYear>2020</publicationYear>
<subjects>
<subject>distillation</subject>
<subject>concentration distribution</subject>
<subject>sieve tray</subject>
<subject>point efficiency</subject>
<subject>tray efficiency</subject>
</subjects>
<dates>
<date dateType="Issued">2020-11-26</date>
</dates>
<language>en</language>
<resourceType resourceTypeGeneral="Dataset"/>
<alternateIdentifiers>
<alternateIdentifier alternateIdentifierType="url">https://rodare.hzdr.de/record/603</alternateIdentifier>
</alternateIdentifiers>
<relatedIdentifiers>
<relatedIdentifier relatedIdentifierType="DOI" relationType="IsReferencedBy">10.1021/acs.iecr.0c05962</relatedIdentifier>
<relatedIdentifier relatedIdentifierType="URL" relationType="IsIdenticalTo">https://www.hzdr.de/publications/Publ-31789</relatedIdentifier>
<relatedIdentifier relatedIdentifierType="URL" relationType="IsReferencedBy">https://www.hzdr.de/publications/Publ-31747</relatedIdentifier>
<relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.14278/rodare.602</relatedIdentifier>
<relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://rodare.hzdr.de/communities/rodare</relatedIdentifier>
<relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://rodare.hzdr.de/communities/topflow</relatedIdentifier>
</relatedIdentifiers>
<rightsList>
<rights rightsURI="info:eu-repo/semantics/restrictedAccess">Restricted Access</rights>
</rightsList>
<descriptions>
<description descriptionType="Abstract"><p>This data contain the outcome of absorbance measurements performed via UV-Spectroscopy on liquid samples containing isobutyl acetate in various concentration. The liquid samples have been taken from several deck positions on a distillation sieve tray to determine the liquid concentration distribution and have been used to determine tray and point efficiency in a post-processing stage.</p></description>
</descriptions>
</resource>
| All versions | This version | |
|---|---|---|
| Views | 1,030 | 1,030 |
| Downloads | 1 | 1 |
| Data volume | 1.4 kB | 1.4 kB |
| Unique views | 651 | 651 |
| Unique downloads | 1 | 1 |