Dataset Open Access
Unger, Sebastian
This dataset contains operating conditions from the TERESA facility during an experimental campaign investigating flooding points of wire mesh demisters (see the associated journal paper for details).
Each row reports time-averaged values over 45 minutes of steady-state operation. Experiments were conducted with the fluid (3M™ Novec™ 649) at saturation conditions defined by system pressure. F-factors are calculated based on a mesh diameter of 275 mm, while individual meshes are differentiated by their specific surface area (column 2).
Fluid properties were computed using REFPROP (v10). Liquid carryover values are corrected (see Appendix A1 of the journal paper). Entries labeled “uncertain” indicate marginal measurements of entrained liquid below the confidence threshold and should be treated as qualitative only.
CSV structure:
Lines 1–2: headers (variable names and units)
Subsequent lines: one experiment per row
Export settings: Windows-1252 encoding; comma-separated fields; double-quote text delimiter
| Name | Size | |
|---|---|---|
|
Experimental data.csv
md5:ecdb24e744f1e4bde89d93956797384b |
18.8 kB | Download |
| All versions | This version | |
|---|---|---|
| Views | 38 | 38 |
| Downloads | 3 | 3 |
| Data volume | 56.2 kB | 56.2 kB |
| Unique views | 35 | 35 |
| Unique downloads | 3 | 3 |