Dataset Restricted Access

Data publication: Investigation of Fouling on Random Packing using Microfocus X-ray Computed Tomography

Inderwies, Korbinian; Boden, Stephan; Schubert, Markus; Klein, Harald; Rehfeldt, Sebastian; Hampel, Uwe


DataCite XML Export

<?xml version='1.0' encoding='utf-8'?>
<resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd">
  <identifier identifierType="DOI">10.14278/rodare.3992</identifier>
  <creators>
    <creator>
      <creatorName>Inderwies, Korbinian</creatorName>
      <givenName>Korbinian</givenName>
      <familyName>Inderwies</familyName>
      <affiliation>Technical University of Munich (TUM), TUM School of Engineering and Design, Department of Energy and Process Engineering, Institute of Plant and Process Technology</affiliation>
    </creator>
    <creator>
      <creatorName>Boden, Stephan</creatorName>
      <givenName>Stephan</givenName>
      <familyName>Boden</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-7170-078X</nameIdentifier>
      <affiliation>Helmholtz-Zentrum Dresden - Rossendorf (HZDR), Institute of Fluid Dynamics</affiliation>
    </creator>
    <creator>
      <creatorName>Schubert, Markus</creatorName>
      <givenName>Markus</givenName>
      <familyName>Schubert</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-6218-0989</nameIdentifier>
      <affiliation>TUD Dresden University of Technology (TUD), Chair of Chemical Process Engineering</affiliation>
    </creator>
    <creator>
      <creatorName>Klein, Harald</creatorName>
      <givenName>Harald</givenName>
      <familyName>Klein</familyName>
      <affiliation>Technical University of Munich (TUM), TUM School of Engineering and Design, Department of Energy and Process Engineering, Institute of Plant and Process Technology</affiliation>
    </creator>
    <creator>
      <creatorName>Rehfeldt, Sebastian</creatorName>
      <givenName>Sebastian</givenName>
      <familyName>Rehfeldt</familyName>
      <affiliation>Technical University of Munich (TUM), TUM School of Engineering and Design, Department of Energy and Process Engineering, Institute of Plant and Process Technology</affiliation>
    </creator>
    <creator>
      <creatorName>Hampel, Uwe</creatorName>
      <givenName>Uwe</givenName>
      <familyName>Hampel</familyName>
      <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-7371-0148</nameIdentifier>
      <affiliation>Helmholtz-Zentrum Dresden - Rossendorf (HZDR), Institute of Fluid Dynamics</affiliation>
    </creator>
  </creators>
  <titles>
    <title>Data publication: Investigation of Fouling on Random Packing using Microfocus X-ray Computed Tomography</title>
  </titles>
  <publisher>Rodare</publisher>
  <publicationYear>2025</publicationYear>
  <subjects>
    <subject>Crystallization Fouling</subject>
    <subject>Random Packing</subject>
    <subject>X-Ray Computed Tomography</subject>
  </subjects>
  <dates>
    <date dateType="Issued">2025-09-24</date>
  </dates>
  <resourceType resourceTypeGeneral="Dataset"/>
  <alternateIdentifiers>
    <alternateIdentifier alternateIdentifierType="url">https://rodare.hzdr.de/record/3992</alternateIdentifier>
  </alternateIdentifiers>
  <relatedIdentifiers>
    <relatedIdentifier relatedIdentifierType="URL" relationType="IsIdenticalTo">https://www.hzdr.de/publications/Publ-41881</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="URL" relationType="IsReferencedBy">https://www.hzdr.de/publications/Publ-41660</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsReferencedBy">10.1021/acs.iecr.5c03093</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.14278/rodare.3991</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://rodare.hzdr.de/communities/rodare</relatedIdentifier>
    <relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://rodare.hzdr.de/communities/topflow</relatedIdentifier>
  </relatedIdentifiers>
  <rightsList>
    <rights rightsURI="info:eu-repo/semantics/restrictedAccess">Restricted Access</rights>
  </rightsList>
  <descriptions>
    <description descriptionType="Abstract">&lt;p&gt;The present dataset comprises the results of X-ray micro-computertomographic (micro-CT) examinations and subsequent quantification of fouling on random packings.&amp;nbsp;A screening test rig was integrated in a micro-CT scanner, enabling high-resolution imaging of crystallization fouling on three industrial random packings (Hiflow 15-7 PP made of polypropylene, Hiflow 20-4 made of ceramic, and Pall-Ring 15 made of metal). Using this technique, initial deposits have been visualized and the non-linear growth of deposits was monitored during the experiment. Quantitative analysis was performed by processing the reconstructed attenuation datasets to determine the volumetric fraction of deposits.&lt;/p&gt;</description>
  </descriptions>
</resource>
411
5
views
downloads
All versions This version
Views 411411
Downloads 55
Data volume 26.6 kB26.6 kB
Unique views 392392
Unique downloads 22

Share

Cite as