Dataset Restricted Access

Neutron imaging and light output calibration with the miniNOVO prototype at the Physikalisch-Technische Bundesanstalt (PTB) Braunschweig

Turko, Joseph; Lutz, Benjamin; Meric, Ilker; Müller, Sara Tabea; Ratliff, Hunter; Römer, Katja Ellen; Urban, Konstantin; Kögler, Toni


JSON-LD (schema.org) Export

{
  "keywords": [
    "NOVO", 
    "Neutron imaging", 
    "Dual particle imaging", 
    "Monoenergetic neutron fields", 
    "Range verification in proton therapy", 
    "PTB"
  ], 
  "identifier": "https://doi.org/10.14278/rodare.3828", 
  "url": "https://rodare.hzdr.de/record/3828", 
  "sameAs": [
    "https://www.hzdr.de/publications/Publ-41530"
  ], 
  "creator": [
    {
      "@type": "Person", 
      "name": "Turko, Joseph", 
      "@id": "https://orcid.org/0000-0002-1400-4120", 
      "affiliation": "Helmholtz-Zentrum Dresden Rossendorf"
    }, 
    {
      "@type": "Person", 
      "name": "Lutz, Benjamin", 
      "@id": "https://orcid.org/0000-0003-3057-7831", 
      "affiliation": "Physikalisch-Technische Bundesanstalt: Braunschweig"
    }, 
    {
      "@type": "Person", 
      "name": "Meric, Ilker", 
      "@id": "https://orcid.org/0000-0001-5659-3907", 
      "affiliation": "Department of Computer science, Electrical engineering and Mathematical sciences, Western Norway University of Applied Science"
    }, 
    {
      "@type": "Person", 
      "name": "M\u00fcller, Sara Tabea", 
      "@id": "https://orcid.org/0000-0003-1916-354X", 
      "affiliation": "OncoRay \u2013 National Center for Radiation Research in Oncology,Helmholtz-Zentrum Dresden Rossendorf"
    }, 
    {
      "@type": "Person", 
      "name": "Ratliff, Hunter", 
      "@id": "https://orcid.org/0000-0003-3761-5415", 
      "affiliation": "Department of Computer science, Electrical engineering and Mathematical sciences, Western Norway University of Applied Science"
    }, 
    {
      "@type": "Person", 
      "name": "R\u00f6mer, Katja Ellen", 
      "@id": "https://orcid.org/0000-0001-6239-4701", 
      "affiliation": "Helmholtz-Zentrum Dresden Rossendorf"
    }, 
    {
      "@type": "Person", 
      "name": "Urban, Konstantin", 
      "@id": "https://orcid.org/0009-0001-2290-5463", 
      "affiliation": "OncoRay \u2013 National Center for Radiation Research in Oncology,Helmholtz-Zentrum Dresden Rossendorf"
    }, 
    {
      "@type": "Person", 
      "name": "K\u00f6gler, Toni", 
      "@id": "https://orcid.org/0000-0002-9501-0898", 
      "affiliation": "OncoRay \u2013 National Center for Radiation Research in Oncology,Helmholtz-Zentrum Dresden Rossendorf"
    }
  ], 
  "name": "Neutron imaging and light output calibration with the miniNOVO prototype at the Physikalisch-Technische Bundesanstalt (PTB) Braunschweig", 
  "inLanguage": {
    "@type": "Language", 
    "alternateName": "eng", 
    "name": "English"
  }, 
  "@type": "Dataset", 
  "datePublished": "2025-06-24", 
  "description": "<p>This data set contains the experimental raw data from the measurement campaign at PTB in March 2024 funded by the European Innovation Council (EIC).</p>\n\n<p><strong>Setup:</strong></p>\n\n<p>The miniNOVO prototype (version 4) consists of 14 organic scintillator elements (7&nbsp;&times;&nbsp;<a href=\"https://doi.org/10.1016/j.nima.2024.169764\">M600</a> and 7&nbsp;&times; <a href=\"https://doi.org/10.1016/j.nima.2021.165778\">organic glas scintillator</a>) of the dimensions <span class=\"math-tex\">\\(12 \u00d7 12 \u00d7 140~\\text{mm}\u00b3\\)</span>. The scintillator bars have dual readout composed of</p>\n\n<ul>\n\t<li>2&nbsp;&times;&nbsp;<a href=\"https://www.hamamatsu.com/content/dam/hamamatsu-photonics/sites/documents/99_SALES_LIBRARY/etd/R7378A_TPMH1288E.pdf\">Hamamatsu R7378A (1&rsquo;&rsquo;) PMTs</a><sup>1</sup>,</li>\n\t<li>4 &times;&nbsp;<a href=\"https://www.hamamatsu.com/eu/en/product/optical-sensors/mppc/mppc_mppc-array/S14161-3050HS-04.html\">Hamamatsu S14161-3050HS-04&nbsp;SiPM</a><sup>1</sup> + U301<sup>2</sup> (+ custom front-end electronics) and</li>\n\t<li>8 &times;&nbsp;<a href=\"https://www.hamamatsu.com/eu/en/product/optical-sensors/pmt/pmt_tube-alone/head-on-type/R2059.html\">Hamamatsu&nbsp;R2059-01 (2&rsquo;&rsquo;) PMTs</a><sup>1</sup>.</li>\n</ul>\n\n<p>The data was recorded with 2 CAEN V1730S<sup>3</sup>&nbsp;14-bit, 16-channel digitizers (named dta and dtb) with a sampling frequency of 500 MS/s. A 1&rsquo;&rsquo; CeBr<sub>3</sub>-detector was employed as a reference detector and positioned centrally behind the array. This detector was used for time calibration and time-of-flight measurements as start detector with a Pu-238 source.</p>\n\n<p>The detector array was irradiated head-on with mono-energetic neutron fields at the <a href=\"https://www.ptb.de/cms/en/ptb/fachabteilungen/abt6/fb-64/642-neutron-metrology/irradiations-and-calibrations.html\">PIAF accelerator facility</a> (Tandetron accelerator) of the energies <span class=\"math-tex\">\\(E_n = \\{ 1.2, 2.5, 6.5, 14.8, 17.0, 19.0\\}~\\text{MeV}\\)</span>. The array position was shifted in two dimensions in 1 cm increments for the <span class=\"math-tex\">\\(14.8~\\text{MeV}\\)</span> measurements, in 5cm increments for <span class=\"math-tex\">\\(17.0~\\text{MeV}\\)</span> and at 1, 2 and 5 cm in both directions for the remaining energies.</p>\n\n<p><strong>Data structure:</strong></p>\n\n<p>The directory <strong>calibration</strong> contains six subdirectories dedicated to the time calibration with the reference detector, the position calibration with a Sr-90 source, the energy calibration with a Bi-207 and a Na-22 source, the gate optimisation and the gain matching. In the <strong>neutron_beam</strong> folder the measurements with the different neutron fields can be found, sorted into the corresponding subdirectory by energy. Waveform data recorded with a Pu-238 source is saved in the <strong>waveform_data</strong> folder and measurements with the reference detector can be found in the <strong>reference_detector</strong> directory. All other measurements and test runs are stored in the <strong>tests</strong> folder.&nbsp;</p>\n\n<p><strong>influxDB</strong> holds the slow control data entries in a csv file and the main configuration files for the digitizers are saved in the <strong>DDAQconfig</strong> folder. In <strong>documentation</strong> a pdf-file of the elog providing more detailed information about the individual data files and a pdf-file with the detector setup are stored.</p>\n\n<p><strong>Data Format:</strong></p>\n\n<p>All data is saved in <a href=\"https://root.cern.ch/doc/master/classTFile.html\">root files</a> which each contain two <a href=\"https://root.cern.ch/doc/master/classTTree.html\">root trees</a>, one for each digitizer, named &ldquo;dta&rdquo; and &ldquo;dtb&rdquo;. The trees hold the following information in the form of listmode data for each event: digitizer channel (&quot;channel&quot;), charge integrated over long gate (&quot;Elong&quot;), charge integrated over short gate (&quot;Eshort&quot;), digitizer flags (&quot;flags&quot;) and the timestamp (separated in three parts: &quot;timestamp&quot;, &quot;timestampExtended&quot;, &quot;time&quot;). Additionally, the root files also contain an TArrayD which denotes the start time of the measurement in UNIX time at its first index and the stop time at its second.</p>\n\n<p>There are two configuration files for each data file (named &ldquo;filename_dtx.config&rdquo;), one for each digitizer card. These text files contain the information about the digitizer settings for each run.</p>\n\n<p>[1]&nbsp;Hamamatsu Photonics Deutschland GmbH,&nbsp;Arzbergerstr. 10, 82211 Herrsching am Ammersee, Germany.</p>\n\n<p>[2] Target Systemelektronik, Heinz-Fangman-Stra&szlig;e 4, 42287 Wuppertal, Germany.&nbsp;</p>\n\n<p>[3] CAEN S.p.A., Via Vetraia 11, 55049 Viareggio (LU), Italy.</p>", 
  "@context": "https://schema.org/", 
  "@id": "https://doi.org/10.14278/rodare.3828"
}
769
14
views
downloads
All versions This version
Views 769769
Downloads 1414
Data volume 295.1 GB295.1 GB
Unique views 685685
Unique downloads 44

Share

Cite as