Dataset Restricted Access

Microfocus X-ray tomography data set of boiling flow in vertical rod bundle with spacer grid at constant heat flux condition

Tas-Köhler, Sibel; Franz, Ronald; Boden, Stephan; Hampel, Uwe


Dublin Core Export

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:creator>Tas-Köhler, Sibel</dc:creator>
  <dc:creator>Franz, Ronald</dc:creator>
  <dc:creator>Boden, Stephan</dc:creator>
  <dc:creator>Hampel, Uwe</dc:creator>
  <dc:date>2020-07-08</dc:date>
  <dc:description>The test section of the rod bundle experimental facility at HZDR consists of a vertically aligned PMMA channel with an upward flow of the working fluid. The cross-section of the channel is quadratic (inner edge length: 37 mm) and contains nine directly electrically heated rods (material: titanium-alloy, diameter: 10 mm, wall thickness: 0.3 mm) which are arranged in an orthogonal 3 by 3 matrix (rod axis distance: 12.8 mm). Circa 190 mm downstream of the start of the heating zone a 30 mm long spacer for the rods with tilted flow guiding vanes is mounted. These vanes are aimed to increase lateral flow velocities within the subchannels. Working fluid was octafluorocyclobutane (CAS 115-25-3, RC318). The experimental facility is comprehensively instrumented for measurement of flow, temperature and pressure/pressure difference. For non-invasive three-dimensional high-resolution measurement of a temporally averaged volumetric void fraction within the working fluid flowing around the heating rods in the subchannels an X-ray computer tomography measurement system was set up.&#13;
The presented dataset contains measurement data of the experimental facility's instrumentation and tomographic void fraction data of experiments with four different configurations of the flow guiding vanes (without vanes, 20°, 29°, 40°) for four different flow velocities between 0.4 m/s and 1.3 m/s at a heat flow density of 85.7 kW/m².</dc:description>
  <dc:description>The data was acquired within a research project which was funded by the Federal Ministry of Economic Affairs and Energy of Germany under grant number 1501473C.</dc:description>
  <dc:identifier>https://rodare.hzdr.de/record/379</dc:identifier>
  <dc:identifier>10.14278/rodare.379</dc:identifier>
  <dc:identifier>oai:rodare.hzdr.de:379</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>url:https://www.hzdr.de/publications/Publ-35438</dc:relation>
  <dc:relation>url:https://www.hzdr.de/publications/Publ-31307</dc:relation>
  <dc:relation>url:https://www.hzdr.de/publications/Publ-35438</dc:relation>
  <dc:relation>url:https://www.hzdr.de/publications/Publ-36690</dc:relation>
  <dc:relation>doi:10.14278/rodare.378</dc:relation>
  <dc:relation>url:https://rodare.hzdr.de/communities/fwd</dc:relation>
  <dc:relation>url:https://rodare.hzdr.de/communities/rodare</dc:relation>
  <dc:rights>info:eu-repo/semantics/restrictedAccess</dc:rights>
  <dc:subject>X-Ray Computed Tomography</dc:subject>
  <dc:subject>Phase fraction</dc:subject>
  <dc:subject>Rod bundle</dc:subject>
  <dc:subject>Boiling flow</dc:subject>
  <dc:title>Microfocus X-ray tomography data set of boiling flow in vertical rod bundle with spacer grid at constant heat flux condition</dc:title>
  <dc:type>info:eu-repo/semantics/other</dc:type>
  <dc:type>dataset</dc:type>
</oai_dc:dc>
1,766
202
views
downloads
All versions This version
Views 1,7661,766
Downloads 202202
Data volume 73.6 GB73.6 GB
Unique views 294294
Unique downloads 1414

Share

Cite as