Dataset Restricted Access

Investigations on Polydisperse gas phase - Static

Windisch, Dominic

Data curator(s)
Bieberle, André
Researcher(s)
Windisch, Dominic; Barthel, Frank

This repository contains sequences of CT images of the two-phase flow in a bubble column consisting of a DN100-PN4 PVC pipe filled with water. As measurement system the ultrafast electron beam X-ray computed tomography scanner was applied in dual plane scanning mode with a dual-imaging frequency of 2,000 Hz. Data containers starting with “SingleBubble” contain image sequences of scans where a single bubble was injected at the bottom of the column using a magnetically operated valve which was open for the time specified in the directory name. Data containers starting with “PolydisperseStatic” contain image sequences of scans where a background flow with 01 to 20 sl/min was induced via a needle sparger in addition to the single bubble (as described before). During each “PolydisperseStatic” scan, the scanning position was fixed at "Hxxx" [mm]. The HDF5 files hold the reconstructed image data (dataset “reco”), each images scanning plane (dataset “plane”), and each images vertical scan position (dataset “scanPosition”).

Restricted Access

You may request access to the files in this upload, provided that you fulfil the conditions below. The decision whether to grant/deny access is solely under the responsibility of the record owner.


Please request for access and cite us.


76
4
views
downloads
All versions This version
Views 7676
Downloads 44
Data volume 21.0 GB21.0 GB
Unique views 5555
Unique downloads 44

Share

Cite as