Software Open Access
Condriuc, Ivan; Kipping, Ragna; Schleicher, Eckhard
<?xml version='1.0' encoding='utf-8'?> <resource xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns="http://datacite.org/schema/kernel-4" xsi:schemaLocation="http://datacite.org/schema/kernel-4 http://schema.datacite.org/meta/kernel-4.1/metadata.xsd"> <identifier identifierType="DOI">10.14278/rodare.3272</identifier> <creators> <creator> <creatorName>Condriuc, Ivan</creatorName> <givenName>Ivan</givenName> <familyName>Condriuc</familyName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0009-0002-1960-179X</nameIdentifier> </creator> <creator> <creatorName>Kipping, Ragna</creatorName> <givenName>Ragna</givenName> <familyName>Kipping</familyName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-6071-1491</nameIdentifier> </creator> <creator> <creatorName>Schleicher, Eckhard</creatorName> <givenName>Eckhard</givenName> <familyName>Schleicher</familyName> <nameIdentifier nameIdentifierScheme="ORCID" schemeURI="http://orcid.org/">0000-0002-6676-5263</nameIdentifier> </creator> </creators> <titles> <title>Data publication: Gas flow rate measurement in two-phase flows using an optical channel body flow sensor. Design and validation of the single-channel prototype</title> </titles> <publisher>Rodare</publisher> <publicationYear>2024</publicationYear> <subjects> <subject>Gas-liquid flow</subject> <subject>Flow patterns</subject> <subject>Taylor-Bubbles</subject> <subject>Flow rate measurement</subject> <subject>Optical fiber</subject> </subjects> <dates> <date dateType="Issued">2024-11-19</date> </dates> <resourceType resourceTypeGeneral="Software"/> <alternateIdentifiers> <alternateIdentifier alternateIdentifierType="url">https://rodare.hzdr.de/record/3272</alternateIdentifier> </alternateIdentifiers> <relatedIdentifiers> <relatedIdentifier relatedIdentifierType="URL" relationType="IsIdenticalTo">https://www.hzdr.de/publications/Publ-39883</relatedIdentifier> <relatedIdentifier relatedIdentifierType="URL" relationType="IsReferencedBy">https://www.hzdr.de/publications/Publ-39711</relatedIdentifier> <relatedIdentifier relatedIdentifierType="DOI" relationType="IsVersionOf">10.14278/rodare.3271</relatedIdentifier> <relatedIdentifier relatedIdentifierType="URL" relationType="IsPartOf">https://rodare.hzdr.de/communities/rodare</relatedIdentifier> </relatedIdentifiers> <rightsList> <rights rightsURI="https://creativecommons.org/licenses/by/4.0/legalcode">Creative Commons Attribution 4.0 International</rights> <rights rightsURI="info:eu-repo/semantics/openAccess">Open Access</rights> </rightsList> <descriptions> <description descriptionType="Abstract"><p>This publication presents the measurement data, including temporal signal changes at measuring points, and validation data, including gas and liquid flow rate measurements, absolute pressure, pressure losses, and temperature, used for the development and investigation of an Optical Channel Body Flow Sensor (OCBFS). The sensor is designed for the simultaneous measurement of gas and liquid flow rates. Experimental validation of the OCBFS was conducted across a range of superficial velocities, with liquid velocities between vl,s = 0.14 0.31 m/s and gas velocities between vg,s = 0.015-0.95 m/s. The results showed deviations of less than 10% from reference values, confirming the sensor’s accuracy and reliability in measuring gas flow rates</p></description> </descriptions> </resource>
All versions | This version | |
---|---|---|
Views | 53 | 53 |
Downloads | 2 | 2 |
Data volume | 2.1 GB | 2.1 GB |
Unique views | 45 | 45 |
Unique downloads | 2 | 2 |