Dataset Restricted Access

CT image sequences of sandwich packings: B1-250 plus B1-500 at constant liquid rate of 20 m³/(m²h) and various gas rates

Sohr, Johanna; Barthel, Frank; Sprewitz, Uwe; Schubert, Markus


Dublin Core Export

<?xml version='1.0' encoding='utf-8'?>
<oai_dc:dc xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:oai_dc="http://www.openarchives.org/OAI/2.0/oai_dc/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.openarchives.org/OAI/2.0/oai_dc/ http://www.openarchives.org/OAI/2.0/oai_dc.xsd">
  <dc:contributor>Barthel, Frank</dc:contributor>
  <dc:contributor>Sohr, Johanna</dc:contributor>
  <dc:contributor>Sprewitz, Uwe</dc:contributor>
  <dc:contributor>Schubert, Markus</dc:contributor>
  <dc:contributor>Bieberle, André</dc:contributor>
  <dc:creator>Sohr, Johanna</dc:creator>
  <dc:creator>Barthel, Frank</dc:creator>
  <dc:creator>Sprewitz, Uwe</dc:creator>
  <dc:creator>Schubert, Markus</dc:creator>
  <dc:date>2024-11-12</dc:date>
  <dc:description>This repository contains sequences of CT images of the two-phase flow in sandwich packings that are alternately arranged in a packing stack using B1-250 (specific geometric surface area is 250 m² /m³) for de-entrainment layer and B1-500 (specific geometric surface area is 500 m² /m³) for holdup layer. As measurement system the ultrafast electron beam X-ray computed tomography scanner was applied in dual plane scanning mode with a dual-imaging frequency of 1000 Hz. Operating parameters, the scanning plane as well as the tags "AB" for de-entrainment layer, "AN" for hold-up layer and "DRIVE" for an axial scan are encoded in the name of the data files.</dc:description>
  <dc:identifier>https://rodare.hzdr.de/record/3212</dc:identifier>
  <dc:identifier>10.14278/rodare.3212</dc:identifier>
  <dc:identifier>oai:rodare.hzdr.de:3212</dc:identifier>
  <dc:language>eng</dc:language>
  <dc:relation>url:https://www.hzdr.de/publications/Publ-39880</dc:relation>
  <dc:relation>doi:10.14278/rodare.3211</dc:relation>
  <dc:relation>url:https://rodare.hzdr.de/communities/fwd</dc:relation>
  <dc:relation>url:https://rodare.hzdr.de/communities/hzdr</dc:relation>
  <dc:relation>url:https://rodare.hzdr.de/communities/rodare</dc:relation>
  <dc:relation>url:https://rodare.hzdr.de/communities/rofex</dc:relation>
  <dc:relation>url:https://rodare.hzdr.de/communities/topflow</dc:relation>
  <dc:rights>info:eu-repo/semantics/restrictedAccess</dc:rights>
  <dc:subject>sandwich packing</dc:subject>
  <dc:subject>two-phase flow</dc:subject>
  <dc:subject>ultrafast electron beam X-ray computed tomography</dc:subject>
  <dc:title>CT image sequences of sandwich packings: B1-250 plus B1-500 at constant liquid rate of 20 m³/(m²h) and various gas rates</dc:title>
  <dc:type>info:eu-repo/semantics/other</dc:type>
  <dc:type>dataset</dc:type>
</oai_dc:dc>
58
0
views
downloads
All versions This version
Views 5858
Downloads 00
Data volume 0 Bytes0 Bytes
Unique views 4545
Unique downloads 00

Share

Cite as