Firebrick RBS ****SOLID ROD BUNDLE DESIGN**** Storage material: 1 HTF: CO2 Mass of Solid medium (Tonne): 392.4859 Length of Solid medium (m): 20 Number of rods: 2791 rod diameter (m): 0.05 Shell diameter (m): 3.8125 ****CHARGING PHASE OUTPUT**** Charging Time (h): 3.35 Fluid mean temperature at time t (°C): 843.3696 Solid mean temperature at time t (°C): 798.5533 Energy stored in solid (MWh): 50.0543 Energy density (MWh/m3): 0.45669 Pressure drop in TES (Bar): 0.0078522 Electric Energy for heating (MWh): 55.0943 Electric Energy for pump (MWh): 0.12744 Charging efficiency (%): 92.1545 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 8.2917 Discharge Phase 1 Fluid mean temperature at time t (°C): 479.8704 Discharge phase 1 Solid mean temperature at time t (°C): 502.0285 Discharge phase 1 Pressure drop in TES (Bar): 0.0016147 Discharge phase 1 Energy recovered FROM solid (MWh): 41.2704 Discharge phase 1 Electric Energy for pump(MWh): 0.026499 Discharging phase 1 efficiency (%): 81.0562 ****DISCHARGING PHASE 2 OUTPUT**** Discharging Time phase 1+2(h): 10.2333 Discharge Phase 2 Fluid mean temperature at time t (°C): 403.1325 Discharge phase 2 Solid mean temperature at time t (°C): 429.9115 Discharge phase 2 Pressure drop in TES (Bar): 0.0030808 Discharge phase 2 Energy recovered FROM solid (MWh): 9.6601 Discharge phase 2 Electric Energy for pump(MWh): 0.0159 Discharging phase 2 efficiency (%): 100.2624 OVERALL TES EFFICICENCY (%) 92.1583 phase I OVERALL TES EFFICICENCY (%) 74.699 Alferrock RBS ****SOLID ROD BUNDLE DESIGN**** Storage material: 2 HTF: CO2 Mass of Solid medium (Tonne): 489.2206 Length of Solid medium (m): 20 Number of rods: 3367 rod diameter (m): 0.05 Shell diameter (m): 4.1875 ****CHARGING PHASE OUTPUT**** Charging Time (h): 3.25 Fluid mean temperature at time t (°C): 824.4067 Solid mean temperature at time t (°C): 779.3313 Energy stored in solid (MWh): 50.0747 Energy density (MWh/m3): 0.37872 Pressure drop in TES (Bar): 0.0056342 Electric Energy for heating (MWh): 55.379 Electric Energy for pump (MWh): 0.072359 Charging efficiency (%): 91.8193 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 7.7917 Discharge Phase 1 Fluid mean temperature at time t (°C): 460.3197 Discharge phase 1 Solid mean temperature at time t (°C): 482.3218 Discharge phase 1 Pressure drop in TES (Bar): 0.0008771 Discharge phase 1 Energy recovered FROM solid (MWh): 38.6775 Discharge phase 1 Electric Energy for pump(MWh): 0.011097 Discharging phase 1 efficiency (%): 75.9483 ****DISCHARGING PHASE 2 OUTPUT**** Discharging Time phase 1+2(h): 9.1333 Discharge Phase 2 Fluid mean temperature at time t (°C): 404.1499 Discharge phase 2 Solid mean temperature at time t (°C): 429.7549 Discharge phase 2 Pressure drop in TES (Bar): 0.0031826 Discharge phase 2 Energy recovered FROM solid (MWh): 6.6755 Discharge phase 2 Electric Energy for pump(MWh): 0.011639 Discharging phase 2 efficiency (%): 13.108 OVERALL TES EFFICICENCY (%) 81.7553 >> ACW RBS ****SOLID ROD BUNDLE DESIGN**** ****SOLID ROD BUNDLE DESIGN**** Storage material: 3 HTF: CO2 Mass of Solid medium (Tonne): 460.2865 Length of Solid medium (m): 20 Number of rods: 3781 rod diameter (m): 0.05 Shell diameter (m): 4.4375 ****CHARGING PHASE OUTPUT**** Charging Time (h): 3.2167 Fluid mean temperature at time t (°C): 822.8246 Solid mean temperature at time t (°C): 781.5073 Energy stored in solid (MWh): 50.0848 Energy density (MWh/m3): 0.33732 Pressure drop in TES (Bar): 0.0074208 Electric Energy for heating (MWh): 54.6946 Electric Energy for pump (MWh): 0.11332 Charging efficiency (%): 92.8837 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 8.325 Discharge Phase 1 Fluid mean temperature at time t (°C): 476.4762 Discharge phase 1 Solid mean temperature at time t (°C): 494.4365 Discharge phase 1 Pressure drop in TES (Bar): 0.0014237 Discharge phase 1 Energy recovered FROM solid (MWh): 41.435 Discharge phase 1 Electric Energy for pump(MWh): 0.023406 Discharging phase 1 efficiency (%): 81.3551 ****DISCHARGING PHASE 2 OUTPUT**** Discharging Time phase 1+2(h): 10.125 Discharge Phase 2 Fluid mean temperature at time t (°C): 408.5768 Discharge phase 2 Solid mean temperature at time t (°C): 429.8797 Discharge phase 2 Pressure drop in TES (Bar): 0.0028685 Discharge phase 2 Energy recovered FROM solid (MWh): 8.9548 Discharge phase 2 Electric Energy for pump(MWh): 0.013778 Discharging phase 2 efficiency (%): 94.3963 OVERALL TES EFFICICENCY (%) 91.8766 Firebrick PPS ****SOLID PARALLEL PLATE DESIGN**** Storage material: 1 HTF: CO2 Mass of Solid medium (Tonne): 396.5958 Length of Solid medium (m): 20 Number of rectangles plates: 1772 thickness plate(m): 0.05 Shell diameter (m): 3.0239 ****CHARGING PHASE OUTPUT**** Charging Time (h): 2.5833 Fluid mean temperature at time t (°C): 836.5895 Solid mean temperature at time t (°C): 794.1528 Energy stored in solid (MWh): 50.0266 Energy density (MWh/m3): 0.45171 Pressure drop in TES (Bar): 0.078004 Electric Energy for heating (MWh): 49.3297 Electric Energy for pump (MWh): 0.8365 Charging efficiency (%): 101.306 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 7.8583 Discharge Phase 1 Fluid mean temperature at time t (°C): 464.6528 Discharge phase 1 Solid mean temperature at time t (°C): 483.6122 Discharge phase 1 Pressure drop in TES (Bar): 0.011787 Discharge phase 1 Energy recovered FROM solid (MWh): 39.0637 Discharge phase 1 Electric Energy for pump(MWh): 0.15032 Discharging phase 1 efficiency (%): 76.638 ****DISCHARGING PHASE 2 OUTPUT**** Discharging Time phase 1+2(h): 9.1833 Discharge Phase 2 Fluid mean temperature at time t (°C): 409.455 Discharge phase 2 Solid mean temperature at time t (°C): 429.754 Discharge phase 2 Pressure drop in TES (Bar): 0.035615 Discharge phase 2 Energy recovered FROM solid (MWh): 6.5919 Discharge phase 2 Electric Energy for pump(MWh): 0.12832 Discharging phase 2 efficiency (%): 12.938 OVERALL TES EFFICICENCY (%) 90.5059 Your MATLAB session has timed out. All license keys have been returned. Alferrock PPS ****SOLID PARALLEL PLATE DESIGN**** Storage material: 2 HTF: CO2 Mass of Solid medium (Tonne): 485.625 Length of Solid medium (m): 20 Number of rectangles plates: 2100 thickness plate(m): 0.05 Shell diameter (m): 3.2891 ****CHARGING PHASE OUTPUT**** Charging Time (h): 2.5917 Fluid mean temperature at time t (°C): 827.7991 Solid mean temperature at time t (°C): 782.3812 Energy stored in solid (MWh): 50.1034 Energy density (MWh/m3): 0.38174 Pressure drop in TES (Bar): 0.061978 Electric Energy for heating (MWh): 49.4959 Electric Energy for pump (MWh): 0.66845 Charging efficiency (%): 101.5093 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 7.8333 Discharge Phase 1 Fluid mean temperature at time t (°C): 463.8279 Discharge phase 1 Solid mean temperature at time t (°C): 482.1155 Discharge phase 1 Pressure drop in TES (Bar): 0.0095026 Discharge phase 1 Energy recovered FROM solid (MWh): 38.9292 Discharge phase 1 Electric Energy for pump(MWh): 0.12499 Discharging phase 1 efficiency (%): 76.2624 ****DISCHARGING PHASE 2 OUTPUT**** Discharging Time phase 1+2(h): 9.1583 Discharge Phase 2 Fluid mean temperature at time t (°C): 408.7085 Discharge phase 2 Solid mean temperature at time t (°C): 429.9167 Discharge phase 2 Pressure drop in TES (Bar): 0.028232 Discharge phase 2 Energy recovered FROM solid (MWh): 6.592 Discharge phase 2 Electric Energy for pump(MWh): 0.10198 Discharging phase 2 efficiency (%): 12.9195 OVERALL TES EFFICICENCY (%) 90.3354 >> ACW PPS ****SOLID PARALLEL PLATE DESIGN**** Storage material: 3 HTF: CO2 Mass of Solid medium (Tonne): 448.3375 Length of Solid medium (m): 20 Number of rectangles plates: 2314 thickness plate(m): 0.05 Shell diameter (m): 3.4543 ****CHARGING PHASE OUTPUT**** Charging Time (h): 2.5833 Fluid mean temperature at time t (°C): 832.6015 Solid mean temperature at time t (°C): 791.0429 Energy stored in solid (MWh): 50.0069 Energy density (MWh/m3): 0.34577 Pressure drop in TES (Bar): 0.053002 Electric Energy for heating (MWh): 49.3557 Electric Energy for pump (MWh): 0.56861 Charging efficiency (%): 101.7576 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 7.925 Discharge Phase 1 Fluid mean temperature at time t (°C): 463.4031 Discharge phase 1 Solid mean temperature at time t (°C): 479.988 Discharge phase 1 Pressure drop in TES (Bar): 0.0078912 Discharge phase 1 Energy recovered FROM solid (MWh): 39.3837 Discharge phase 1 Electric Energy for pump(MWh): 0.1037 Discharging phase 1 efficiency (%): 77.3663 ****DISCHARGING PHASE 2 OUTPUT**** Discharging Time phase 1+2(h): 9.1667 Discharge Phase 2 Fluid mean temperature at time t (°C): 410.776 Discharge phase 2 Solid mean temperature at time t (°C): 429.8476 Discharge phase 2 Pressure drop in TES (Bar): 0.024213 Discharge phase 2 Energy recovered FROM solid (MWh): 6.1768 Discharge phase 2 Electric Energy for pump(MWh): 0.082229 Discharging phase 2 efficiency (%): 12.1389 OVERALL TES EFFICICENCY (%) 90.9205 Firebrick RSS ****SOLID rectangular block**** Storage material: 1 HTF: CO2 Mass of Solid medium (Tonne): 406.0854 Length of Solid medium (m): 20 Number of rectangles plates: 1134 thickness plate(m): 0.05 Shell diameter (m): 3.4328 ****CHARGING PHASE OUTPUT**** Charging Time (h): 2.5417 Fluid mean temperature at time t (°C): 821.925 Solid mean temperature at time t (°C): 784.8192 Energy stored in solid (MWh): 50.0242 Energy density (MWh/m3): 0.44113 Pressure drop in TES (Bar): 0.017867 Electric Energy for heating (MWh): 49.0042 Electric Energy for pump (MWh): 0.18432 Charging efficiency (%): 103.2676 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 7.9833 Discharge Phase 1 Fluid mean temperature at time t (°C): 461.9844 Discharge phase 1 Solid mean temperature at time t (°C): 476.9673 Discharge phase 1 Pressure drop in TES (Bar): 0.0025143 Discharge phase 1 Energy recovered FROM solid (MWh): 39.6643 Discharge phase 1 Electric Energy for pump(MWh): 0.033023 Discharging phase 1 efficiency (%): 78.0351 ****DISCHARGING PHASE 2 OUTPUT**** Discharging Time phase 1+2(h): 9.1667 Discharge Phase 2 Fluid mean temperature at time t (°C): 413.3818 Discharge phase 2 Solid mean temperature at time t (°C): 429.9224 Discharge phase 2 Pressure drop in TES (Bar): 0.0081488 Discharge phase 2 Energy recovered FROM solid (MWh): 5.886 Discharge phase 2 Electric Energy for pump(MWh): 0.026299 Discharging phase 2 efficiency (%): 11.5815 OVERALL TES EFFICICENCY (%) 92.492 >> Alferrock RSS ****SOLID rectangular block**** Storage material: 2 HTF: CO2 Mass of Solid medium (Tonne): 479.52 Length of Solid medium (m): 20 Number of rectangles plates: 1296 thickness plate(m): 0.05 Shell diameter (m): 3.6599 ****CHARGING PHASE OUTPUT**** Charging Time (h): 2.55 Fluid mean temperature at time t (°C): 826.1465 Solid mean temperature at time t (°C): 787.13 Energy stored in solid (MWh): 50.1185 Energy density (MWh/m3): 0.38672 Pressure drop in TES (Bar): 0.016173 Electric Energy for heating (MWh): 49.3731 Electric Energy for pump (MWh): 0.16847 Charging efficiency (%): 102.741 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 8 Discharge Phase 1 Fluid mean temperature at time t (°C): 461.5422 Discharge phase 1 Solid mean temperature at time t (°C): 477.1211 Discharge phase 1 Pressure drop in TES (Bar): 0.0021929 Discharge phase 1 Energy recovered FROM solid (MWh): 39.7436 Discharge phase 1 Electric Energy for pump(MWh): 0.028787 Discharging phase 1 efficiency (%): 78.0385 ****DISCHARGING PHASE 2 OUTPUT**** Discharging Time phase 1+2(h): 9.1833 Discharge Phase 2 Fluid mean temperature at time t (°C): 412.8209 Discharge phase 2 Solid mean temperature at time t (°C): 429.872 Discharge phase 2 Pressure drop in TES (Bar): 0.0072224 Discharge phase 2 Energy recovered FROM solid (MWh): 5.886 Discharge phase 2 Electric Energy for pump(MWh): 0.023291 Discharging phase 2 efficiency (%): 11.5587 OVERALL TES EFFICICENCY (%) 92.007 ACW RSS ****SOLID rectangular block**** Storage material: 3 HTF: CO2 Mass of Solid medium (Tonne): 443.3 Length of Solid medium (m): 20 Number of rectangles plates: 1430 thickness plate(m): 0.05 Shell diameter (m): 3.8537 ****CHARGING PHASE OUTPUT**** Charging Time (h): 2.5583 Fluid mean temperature at time t (°C): 832.3818 Solid mean temperature at time t (°C): 795.8383 Energy stored in solid (MWh): 50.0767 Energy density (MWh/m3): 0.35019 Pressure drop in TES (Bar): 0.013804 Electric Energy for heating (MWh): 49.075 Electric Energy for pump (MWh): 0.14406 Charging efficiency (%): 103.2986 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 8.0833 Discharge Phase 1 Fluid mean temperature at time t (°C): 460.7779 Discharge phase 1 Solid mean temperature at time t (°C): 475.5508 Discharge phase 1 Pressure drop in TES (Bar): 0.0018393 Discharge phase 1 Energy recovered FROM solid (MWh): 40.15 Discharge phase 1 Electric Energy for pump(MWh): 0.024176 Discharging phase 1 efficiency (%): 78.9316 ****DISCHARGING PHASE 2 OUTPUT**** Discharging Time phase 1+2(h): 9.2 Discharge Phase 2 Fluid mean temperature at time t (°C): 413.7191 Discharge phase 2 Solid mean temperature at time t (°C): 429.9048 Discharge phase 2 Pressure drop in TES (Bar): 0.0061875 Discharge phase 2 Energy recovered FROM solid (MWh): 5.5536 Discharge phase 2 Electric Energy for pump(MWh): 0.018832 Discharging phase 2 efficiency (%): 10.919 OVERALL TES EFFICICENCY (%) 92.7763 Firebrick CES ****channel DESIGN**** Storage material: 1 HTF: CO2 Mass of Solid medium (Tonne): 463.9468 Length of Solid medium (m): 20 Number of rods: 222769 rod diameter (m): 0.005 Shell diameter (m): 4.0875 ****CHARGING PHASE OUTPUT**** Charging Time (h): 2.325 Fluid mean temperature at time t (°C): 743.0246 Solid mean temperature at time t (°C): 737.5478 Energy stored in solid (MWh): 50.1395 Energy density (MWh/m3): 0.387 Pressure drop in TES (Bar): 0.0096224 Electric Energy for heating (MWh): 51.6729 Electric Energy for pump (MWh): 0.086761 Charging efficiency (%): 98.2705 ****DISCHARGING PHASE1 OUTPUT**** 94 Discharge Phase 1 Fluid mean temperature at time t (°C): 431.583 Discharge phase 1 Solid mean temperature at time t (°C): 433.2407 Discharge phase 1 Pressure drop in TES (Bar): 0.00070825 Discharge phase 1 Energy recovered FROM solid (MWh): 44.3502 Discharge phase 1 Electric Energy for pump(MWh): 0.0087217 Discharging phase 1 efficiency (%): 87.1779 ****DISCHARGING PHASE 2 OUTPUT**** Discharging Time phase 1+2(h): 9.0833 Discharge Phase 2 Fluid mean temperature at time t (°C): 427.8225 Discharge phase 2 Solid mean temperature at time t (°C): 429.81 Discharge phase 2 Pressure drop in TES (Bar): 0.0040569 Discharge phase 2 Energy recovered FROM solid (MWh): 0.49428 Discharge phase 2 Electric Energy for pump(MWh): 0.0010819 Discharging phase 2 efficiency (%): 0.97173 OVERALL TES EFFICICENCY (%) 86.6234 Alferrock CES ****channel DESIGN**** Storage material: 2 HTF: CO2 Mass of Solid medium (Tonne): 552.3117 Length of Solid medium (m): 20 Number of rods: 256669 rod diameter (m): 0.005 Shell diameter (m): 4.3875 ****CHARGING PHASE OUTPUT**** Charging Time (h): 2.325 Fluid mean temperature at time t (°C): 740.9193 Solid mean temperature at time t (°C): 736.1647 Energy stored in solid (MWh): 50.1368 Energy density (MWh/m3): 0.33587 Pressure drop in TES (Bar): 0.0090418 Electric Energy for heating (MWh): 51.6739 Electric Energy for pump (MWh): 0.081525 Charging efficiency (%): 98.2801 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 9.0917 Discharge Phase 1 Fluid mean temperature at time t (°C): 428.0389 Discharge phase 1 Solid mean temperature at time t (°C): 429.5076 Discharge phase 1 Pressure drop in TES (Bar): 0.0006239 Discharge phase 1 Energy recovered FROM solid (MWh): 44.7906 Discharge phase 1 Electric Energy for pump(MWh): 0.0074218 Discharging phase 1 efficiency (%): 88.0444 ****DISCHARGING PHASE 2 OUTPUT dosnt exist**** aaa = 'NO DISCHARGING 2' OVERALL TES EFFICICENCY (%) 86.5304 >> ACW CES ****channel DESIGN**** Storage material: 3 HTF: CO2 Mass of Solid medium (Tonne): 521.4535 Length of Solid medium (m): 20 Number of rods: 289231 rod diameter (m): 0.005 Shell diameter (m): 4.6575 ****CHARGING PHASE OUTPUT**** Charging Time (h): 2.325 Fluid mean temperature at time t (°C): 741.1405 Solid mean temperature at time t (°C): 736.9208 Energy stored in solid (MWh): 50.1342 Energy density (MWh/m3): 0.29804 Pressure drop in TES (Bar): 0.0085796 Electric Energy for heating (MWh): 51.6742 Electric Energy for pump (MWh): 0.077356 Charging efficiency (%): 98.2781 ****DISCHARGING PHASE1 OUTPUT**** Discharging Time phase1(h): 9.1167 Discharge Phase 1 Fluid mean temperature at time t (°C): 427.4529 Discharge phase 1 Solid mean temperature at time t (°C): 428.7607 Discharge phase 1 Pressure drop in TES (Bar): 0.00058431 Discharge phase 1 Energy recovered FROM solid (MWh): 44.8973 Discharge phase 1 Electric Energy for pump(MWh): 0.0068851 Discharging phase 1 efficiency (%): 88.2634 ****DISCHARGING PHASE 2 OUTPUT dosnt exist**** aaa = 'NO DISCHARGING 2' OVERALL TES EFFICICENCY (%) 86.7438 Discharging phase 2 efficiency (%): 2.0271 OVERALL TES EFFICICENCY (%) 86.5042